The LRFR series Fouling Resistant Reverse Osmosis membrane elements are specifically designed to handle source water with high fouling potential. Utilizing special membrane surface modification and flow channel design, they significantly reduce the rate of adsorption and deposition of pollutants such as organic matter, colloids, and microorganisms on the membrane surface. While maintaining high salt rejection (99.5%-99.8%), this series notably extends chemical cleaning intervals, reducing maintenance frequency and cost. It is a reliable choice for treating municipal wastewater, industrial effluent, surface water, and other challenging water qualities.
Excellent Fouling Resistance: Optimized surface properties and structure effectively resist organic, biological, and colloidal fouling, maintaining stable membrane flux over the long term.
Stable High Rejection Performance: Even when facing complex feed water, it maintains excellent salt rejection as high as 99.8%, producing consistently compliant, high-quality pure water.
Reduced Operational and Maintenance Costs: Longer cleaning cycles reduce chemical usage, downtime, and labor maintenance costs, improving overall system availability and economy.
Suitable for Challenging Water Sources: The preferred membrane element for wastewater reuse, surface water treatment, and desalination projects with high fouling potential feed water.
The LRFR series is designed for high-fouling-risk water sources. Its core applications include:
Municipal and Industrial Wastewater Advanced Treatment and Reuse (Reclaimed Water): Serves as the core desalination unit following MBR or UF, treating secondary effluent, resisting organic and microbial fouling to produce high-quality reuse water.
Surface Water (River, Lake Water) Purification: Directly treats surface water containing significant colloids, organic matter, and microorganisms to produce industrial or potable water, with more stable system operation.
Landfill Leachate Treatment Systems: Used for volume reduction treatment of leachate membrane concentrate. Its strong fouling resistance can handle extremely high COD and scaling ion loads.
Food, Paper, Textile, and Other Industry Process Water Recovery: Treats complex, high-organic-load process wastewater to recover water resources and reduce discharge.
| Model | Average Water Production | Stable Salt Rejection | Membrane Area |
| LRFR8040-5CH | 10,500 GPD (39.7 m³/d) | 99.6% | 400 ft² (37.2 m²) |
| LRFR8040-5BH | 10,500 GPD (39.7 m³/d) | 99.75% | 400 ft² (37.2 m²) |
| LRFR8040-3AH | 11,500 GPD (43.5 m³/d) | 99.8% | 400 ft² (37.2 m²) |
| LRFR8040-5D | 10,500 GPD (39.7 m³/d) | 99.5% | 400 ft² (37.2 m²) |
| LRFR8040-5C | 10,500 GPD (39.7 m³/d) | 99.6% | 400 ft² (37.2 m²) |
| LRFR4040-3D | 2,200 GPD (8.3 m³/d) | 99.5% | 90 ft² (8.4 m²) |
The LRHOR series Chlorine Tolerant Reverse Osmosis membrane elements are specialized membrane products...
The LRLP series Low Pressure Reverse Osmosis membrane elements represent a further optimization in operating...
The LRSW series Seawater Desalination Reverse Osmosis membrane elements are professional-grade desalination...
The LRULP series Ultra-Low Pressure Reverse Osmosis membrane elements represent the advanced level of...
The LNDM series nanofiltration membrane elements are high-performance membrane products meticulously...
The LGJ1 type ultrafiltration membrane module is a high-performance submerged membrane stack designed...
The LGJ2C-2000X140 submerged ultrafiltration membrane module is the flagship integrated membrane stack...
The LW type pressure ultrafiltration membrane components and their integrated LGW-type equipment are...
The LH type pressure ultrafiltration membrane components and their integrated systems are high-performance...
A: You receive comprehensive water treatment services including detailed system documentation, operator training, warranty coverage, and access to our technical support team. We also offer optional annual maintenance contracts for long-term industrial water system support.
A: We maintain strategic inventory of critical water treatment spare parts. For urgent needs, we expedite shipping to minimize your RO system maintenance downtime. Our support team manages parts identification and logistics.
A: We prioritize emergency cases. For critical issues halting operation, we provide initial response within 4-8 business hours and work relentlessly to resolve problems, leveraging remote diagnostics for water treatment maintenance.
A: Yes. We offer comprehensive training during water plant commissioning, covering normal operation, routine water treatment maintenance, and basic troubleshooting procedures.
A: Absolutely. Our systems feature modular design. We can reassess needs and provide retrofit solutions or capacity expansions through our water treatment services to adapt to changing conditions.
Contact Our OEM/ODM Specialists Now
Tell us about your initial idea, and we will provide a preliminary feasibility analysis and recommendations within one business day.